Interpretation guide
Open switch, healthy feed: TP1 is near B+ and TP2 is near 0 V (the intact lamp provides a path to ground). Nearly full source voltage appears across the open switch.
Closed switch, healthy circuit: TP1 and TP2 are near B+. Voltage drop across the closed switch should be near 0 V; most supply voltage is across the lamp.
Open lamp ground: TP3 may rise near B+ with the switch closed, even though the lamp remains dark, because no current flows and there is no load voltage drop.
Safety note: Never measure resistance on an energized circuit. For a real current test, connect the meter according to its rating and the approved service procedure; do not place an ammeter directly across a battery or source.