Make a fault appear. Collect evidence while it is present. Find the precise failure—without replacing a good component.
10 short lessonsLive circuit & meterTrigger-based faultsMystery diagnostic missions
Your course progress0 / 10 lessons • Assessment pending
01 / Learn the fault
Lesson 1 of 10
02 / Circuit workbench
12.6 V • 10 A fuse • 6 Ω lamp
Model: a simplified, fused 12 V lamp circuit with a power wire, in-line connector, load and chassis ground. Component labels are educational, not OEM pinouts.
Fuse intact
LampON
Current2.04 A
Load voltage12.3 V
Power25.0 W
03 / Virtual meter & scope
DC volts: select two test points. Voltage displayed = potential at red lead − potential at black lead. A voltage-drop test is performed across a connection while the circuit is carrying current.
Load a hidden fault, reproduce the symptom, make measurements, then identify the best-supported fault. The same circuit model powers the mystery bay and the workbench above.
No mystery loaded
Customer statement
The lamp sometimes stops working. The customer reports that the symptom is difficult to duplicate.
Evidence notebook
No readings logged.
Technician's workflow
1. Verify complaint; note when it occurs.
2. Reproduce with vibration, heat, or moisture.
3. Compare power-side and ground-side voltage drops under load.
4. Isolate the affected section; inspect and repair per service information.
5. Recheck under the original triggering condition.
05 / Final knowledge check
Six questions. Score at least five correct to pass; you can retry. Use observations from the virtual lab before deciding.